Search for collections on EPrints Repository UNTIRTA

STUDI PENGARUH VARIASI ARUS E420-13 LOKAL DAN E6013 IMPOR TERHADAP SIFAT MEKANIK DAN STRUKTUR MIKRO PADA PLAT ASTM A36 DENGAN METODE PENGELASAN SMAW

Haziemill Akbar, Muhammad Ae (2024) STUDI PENGARUH VARIASI ARUS E420-13 LOKAL DAN E6013 IMPOR TERHADAP SIFAT MEKANIK DAN STRUKTUR MIKRO PADA PLAT ASTM A36 DENGAN METODE PENGELASAN SMAW. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa.

[img] Text
Muhammad Ae Haziemill Akbar_3334190101_Fulltext.pdf

Download (3MB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_01.pdf

Download (929kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_02.pdf

Download (399kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_03.pdf

Download (247kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_03.pdf

Download (247kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_04.pdf

Download (1MB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_05.pdf

Download (34kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_Ref..pdf

Download (37kB)
[img] Text
Muhammad Ae Haziemill Akbar_3334190101_Lamp..pdf

Download (1MB)

Abstract

The growth of the welding wire industry is currently growing rapidly. The domestic welding wire industry with various manufacturers such as E6013 Imported is one of the market leaders in Indonesia. Given the increasing growth of the domestic welding wire industry entering the market include E420-13 Local. In the welding wire industry there are still many electrodes that have not been standardized in accordance with standards that refer to the AWS A5.1 standard. The electrode is called a welding wire which is a stick-shaped object used in the welding process. stick which is used in the welding process for the connection of two metals using electrical energy. metals using electrical energy. The type of electrode will affect welding results and the current strength will affect the welding results, because the The right current will produce good penetration. Therefore, this research was conducted on electrodes that are still not standardized and compared with electrodes that are not standardized. electrodes that have not been standardized and compared with electrodes that have been standardized according to the standard. in accordance with the standard. In this study using electrodes in accordance with AWS E6013 standard using ASTM A36 plates using variations of currents of 120 A, 155 A and 190 A. This is done to find out the comparison and determine the quality of the welded joints. comparison and determine the quality of the welded joints of the two electrodes and the current variations used. and current variations used. Tests were carried out on the results of the weld connection, The tests carried out are XRF testing to determine the percentage of flux, radiographic testing to determine the defects produced in the welding process, mechanical testing such as tensile testing, mechanical testing such as tensile testing, and mechanical testing. welding process, mechanical testing such as tensile, impact, and bending testing, and metallographic testing to determine the phase structure. metallographic testing to determine the microstructure phase formed in the weld joint. the result of the weld joint. From the results obtained that Imported E6013 electrode electrode has better characteristics than E420-13. Local.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
Thesis advisorZulaida, Yeni Muriani197401032005012001
Thesis advisorSuhartono, H. Agus196709031992021001
Additional Information: Pertumbuhan industri kawat las saat ini sedang berkembang dengan pesat. Industri kawat las dalam negeri dengan berbagai produsen seperti E6013 Impor merupakan salah satu market leader di Indonesia. Mengingat meningkatnya pertumbuhan industri kawat las dalam negeri yang memasuki pasar antara lain E420-13 Lokal. Pada industri kawat las masih banyak elektroda yang belum terstandarisasi sesuai dengan standar yang mengacu kepada standar AWS A5.1 Elektroda disebut dengan kawat las yang merupakan sebuah benda yang berbentuk stick yang digunakan dalam proses pengelasan untuk proses penyambungan dua logam dengan menggunakan energi listrik. Jenis elektroda akan mempengaruhi hasil pengelasan dan kuat arus akan mempengaruhi hasil pengelasan, dikarenakan arus yang tepat akan menghasilkan penetrasi yang baik. Oleh sebab itu, penelitian ini dilakukan pada elektroda yang masih belum terstandarisasi dan dibandingkan dengan elektroda yang sudah terstandarisasi sesuai dengan standar. Pada penelitian ini menggunakan elektroda sesuai dengan standar AWS E6013 menggunakan plat ASTM A36 dengan menggunakan variasi arus 120 A, 155 A dan 190 A. Hal tersebut dilakukan untuk mengetahui perbandingan dan mengetahui kualitas hasil sambungan lasan dari kedua elektroda dan variasi arus yang digunakan. Pengujian dilakukan pada hasil sambungan lasan, pengujian yang dilakukan adalah pengujian XRF untuk mengetahui persentase flux, pengujian radiografi untuk mengetahui cacat yang dihasilkan pada proses pengelasan, pengujian mekanik seperti pengujian tarik, impak, dan bending, dan pengujian metalografi untuk mengetahui fasa strukturmikro yang terbentuk pada hasil sambungan lasan. Dari hasil yang didapatkan bahwa elektroda E6013 Impor lebih baik memiliki karakteristik yang lebih baik dibandingkan dengan E420-13 Lokal
Subjects: T Technology > TH Building construction
T Technology > TJ Mechanical engineering and machinery
T Technology > TS Manufactures
Divisions: 03-Fakultas Teknik
03-Fakultas Teknik > 27201-Jurusan Teknik Metalurgi
Depositing User: S1 Muhammad Ae Haziemill Akbar Teknik Metalurgi
Date Deposited: 26 Mar 2024 14:53
Last Modified: 26 Mar 2024 14:53
URI: http://eprints.untirta.ac.id/id/eprint/34533

Actions (login required)

View Item View Item