Search for collections on EPrints Repository UNTIRTA

ANALISIS KETIDAKNORMALAN PENGUKURAN ENERGI LISTRIK PADA SISTEM AUTOMATIC METER READING (AMR) PT. PLN UP3 BANTEN UTARA

KHAIRUNNISA, ARINDA (2025) ANALISIS KETIDAKNORMALAN PENGUKURAN ENERGI LISTRIK PADA SISTEM AUTOMATIC METER READING (AMR) PT. PLN UP3 BANTEN UTARA. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa.

[img] Text (Fulltext)
Arinda Khairunnisa_3332210098_Fulltext.pdf
Restricted to Registered users only

Download (4MB)
[img] Text (Bab 1)
Arinda Khairunnisa_3332210098_01.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (Bab 2)
Arinda Khairunnisa_3332210098_02.pdf
Restricted to Registered users only

Download (751kB)
[img] Text (Bab 3)
Arinda Khairunnisa_3332210098_03.pdf
Restricted to Registered users only

Download (554kB)
[img] Text (Bab 4)
Arinda Khairunnisa_3332210098_04.pdf
Restricted to Registered users only

Download (721kB)
[img] Text (Bab 5)
Arinda Khairunnisa_3332210098_05.pdf
Restricted to Registered users only

Download (239kB)
[img] Text (Daftar Referensi)
Arinda Khairunnisa_3332210098_Ref.pdf
Restricted to Registered users only

Download (248kB)
[img] Text (Lampiran)
Arinda Khairunnisa_3332210098_Lamp.pdf
Restricted to Registered users only

Download (2MB)
[img] Text (Cek Plagiasi)
Arinda Khairunnisa_3332210098_CP.pdf
Restricted to Registered users only

Download (20MB)

Abstract

In the conventional method, electricity consumption was recorded manually by personnel who visited customers’ premises; however, this approach often led to errors. To overcome this issue, the electricity company installed electronic meters connected to the Automatic Meter Reading (AMR) system as a tool to automatically and in real-time record energy usage. Nevertheless, the AMR system still experienced measurement abnormalities caused by both technical and non-technical disturbances. These abnormalities resulted in inaccurately measured energy, leading to energy and financial losses, as well as billing inaccuracies that ultimately triggered the issuance of back billing to customers. This study aimed to analyze the characteristics of energy measurement abnormalities, identify their causes, and calculate the resulting energy and financial losses. The method used involved analyzing measurement results from the AMR system, including load profiles, instantaneous data, and historical electricity usage of customers. The findings revealed abnormalities such as unbalanced current, unbalanced voltage, and blank kWh meters, with total energy losses reaching 188.043,517 kWh and financial losses amounting to IDR 190.558.308,325. These abnormalities were caused by technical issues such as broken CT jumper cables, tripped CVT MCBs, and non-technical causes such as blank kWh meters due to external factors.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
Thesis advisorOTONG, MUHAMAD197203192005011001
Thesis advisorNUGRAHA, ADI199507082022031009
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: 03-Fakultas Teknik > 20201-Jurusan Teknik Elektro
Depositing User: Arinda Khairunnisa
Date Deposited: 16 Jul 2025 02:07
Last Modified: 16 Jul 2025 02:07
URI: http://eprints.untirta.ac.id/id/eprint/51670

Actions (login required)