Search for collections on EPrints Repository UNTIRTA

PEMANTAUAN DETAK JANTUNG DAN SATURASI OKSIGEN DALAM DARAH BERBASIS IOT MENGGUNAKAN SENSOR MAX30102

Gunawan, Fajar (2023) PEMANTAUAN DETAK JANTUNG DAN SATURASI OKSIGEN DALAM DARAH BERBASIS IOT MENGGUNAKAN SENSOR MAX30102. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa.

[img] Text (Fajar Gunawan_3332170005_Fulltext)
Fajar Gunawan_3332170005_Fulltext.pdf

Download (1MB)
[img] Text (Fajar Gunawan_3332170005_01)
Fajar Gunawan_3332170005_01.pdf

Download (354kB)
[img] Text (Fajar Gunawan_3332170005_02)
Fajar Gunawan_3332170005_02.pdf

Download (372kB)
[img] Text (Fajar Gunawan_3332170005_03)
Fajar Gunawan_3332170005_03.pdf

Download (438kB)
[img] Text (Fajar Gunawan_3332170005_04)
Fajar Gunawan_3332170005_04.pdf

Download (434kB)
[img] Text (Fajar Gunawan_3332170005_05)
Fajar Gunawan_3332170005_05.pdf

Download (50kB)
[img] Text (Fajar Gunawan_3332170005_Ref)
Fajar Gunawan_3332170005_Ref.pdf

Download (125kB)
[img] Text (Fajar Gunawan_3332170005_Lamp)
Fajar Gunawan_3332170005_Lamp.pdf

Download (211kB)
[img] Text (Fajar Gunawan_3332170005_CP)
Fajar Gunawan_3332170005_CP.pdf

Download (16MB)

Abstract

A condition where abnormal levels of oxygen in the blood (SpO2) can disrupt the function of the body's organs and tissues. The COVID-19 pandemic has exacerbated this condition because the coronavirus attacks haemoglobin in red blood cells, causing shortness of breath and death. To measure SpO2 and BPM, a non-invasive, photoplethysmography-based device is used that helps health workers to health workers to obtain SpO2 and BPM values without harming the patient. In the manufacture of SpO2 and BPM measurement tools, MAX30102 sensors are used with the Reflectance photoplethysmography method and ESP8266 WiFi module so that it can be monitored using the Blynk platform. In this study, SpO2 and BPM measurements were conducted on 20 people with an age range of 7 to 15 years and 20 to 60 years, while SpO2 values at the age of 7 to 15 years tend to be stable. Measurements were taken in a relaxed state without strenuous activity. Some of the factors that affect SpO2 and BPM values on this device are movement, physical activity, environmental light intensity, and noise from other electronic devices. This thesis successfully developed a SpO2 and BPM measurement tool using sensors with the photoplethysmography method, which can facilitate patient monitoring.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
UNSPECIFIEDSARASWATI, IRMA0024077803
UNSPECIFIEDALFANZ, ROCKY0028038103
Additional Information: Kondisi ketika kadar Oksigen dalam Darah (SpO2) yang tidak normal dapat mengganggu fungsi organ dan jaringan tubuh. Pandemi COVID-19 memperparah kondisi ini karena virus corona menyerang hemoglobin dalam sel darah merah, menyebabkan sesak nafas dan kematian. Untuk mengukur SpO2 dan BPM, digunakan alat non-invasif berbasis photoplethysmography yang membantu tenaga kesehatan mendapatkan nilai SpO2 dan BPM tanpa melukai pasien. Dalam pembuatan alat pengukuran SpO2 dan BPM, digunakan sensor MAX30102 dengan metode photoplethysmography Reflectance dan modul WiFi ESP8266 agar dapat dipantau menggunakan platform Blynk. Penelitian ini, dilakukan pengukuran SpO2 dan BPM pada 20 orang dengan rentang usia 7 sampai 15 tahun dan 20 sampai 60 tahun, sementara nilai SpO2 pada usia 7 sampai 15 tahun cenderung stabil. Pengukuran dilakukan dalam keadaan rileks tanpa aktivitas berat. Beberapa faktor yang mempengaruhi nilai SpO2 dan BPM pada alat ini adalah Gerakan, aktivitas fisik, intensitas cahaya lingkungan, dan noise dari perangkat elektronik lainnya. Skripsi ini berhasil mengembangkan alat pengukuran SpO2 dan BPM menggunakan sensor dengan metode photoplethysmography, yang dapat memudahkan pemantauan pasien.
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: 03-Fakultas Teknik
03-Fakultas Teknik > 20201-Jurusan Teknik Elektro
Depositing User: Mr Gunawan Fajar
Date Deposited: 31 Oct 2023 10:57
Last Modified: 31 Oct 2023 10:57
URI: http://eprints.untirta.ac.id/id/eprint/30726

Actions (login required)

View Item View Item