eprintid: 52584 rev_number: 15 eprint_status: archive userid: 22173 dir: disk0/00/05/25/84 datestamp: 2025-07-24 02:20:09 lastmod: 2025-07-24 02:20:09 status_changed: 2025-07-24 02:20:09 type: thesis metadata_visibility: show contact_email: 3332200078@untirta.ac.id creators_name: Fadlika, Farhan creators_id: 3332200078 contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_name: Muhamad, Otong contributors_name: Felycia, Felycia contributors_id: 197203192005011001 contributors_id: 199202112022032013 corp_creators: UNIVERSITAS SULTAN AGENG TIRTAYASA corp_creators: FAKULTAS TEKNIK corp_creators: JURUSAN TEKNIK ELEKTRO title: ANALISIS PENGUJIAN KONDISI ISOLASI PADA BELITAN TAP CHANGER DAN BUSHING TRANSFORMATOR DI PT INDONESIA POWER SURALAYA ispublished: pub subjects: TK divisions: Elektro full_text_status: restricted abstract: Sistem isolasi transformator berperan penting dalam sistem kelistrikan. Seiring waktu sistem isolasi rentan mengalami penurunan atau degradasi. Penelitian ini bertujuan untuk menganalisis kondisi isolasi tranformator terutama pada komponen belitan, tap changer, dan bushing di PT Indonesia Power Suralaya dengan menggunakan metode indeks polarisasi, tangen delta, dan rasio tegangan. Metode indeks polarisasi dilakukan dengan mengukur perbandingan tahanan isolasi pada menit ke-1 dan ke-10. Metode tangen delta mengukur kerugian daya dielektrik berdasarkan arus resistif dan kapasitif. Metode rasio tegangan memastikan kestabilan perbandingan tegangan primer dan sekunder. Hasil pengujian indeks polarisasi menghasilkan nilai pada kisaran 1.21 sampai 1,78 yang berada di bawah batas standar 1,25 mengindikasikan adanya kelembapan atau degradasi ringan. Nilai tangen delta pada bagian primer ICH sebesar 1,17% dan 1,01% pada bagian ICLT sekunder yang menandakan adanya kontaminasi dan deteriorisasi akibat penuaan. Sementara itu rasio tegangan menghasilkan nilai deviasi di atas 0,5% pada tap 11 sampai 15 yang menandakan adanya shorted turn pada belitan. Penggunaan ketiga metode ini mampu memberikan gambaran menyeluruh dan mencegah terjadinya kerusakan dini terhadap isolasi transformator. Kata Kunci: Transformator, Isolasi, Indeks Polarisasi, Tangen Delta, Rasio Tegangan date: 2025-06-12 date_type: published pages: 92 institution: Fakultas Teknik Universitas Sultan Ageng Tirtayasa department: TEKNIK ELEKTRO thesis_type: sarjana thesis_name: sarjana referencetext: [1] Ondrialdin R., U. Situmeang, and Zulfahri, “Analisis Pengujian Kualitas Isolasi Transformator Daya di PT. Indah Kiat Pulp and Paper Perawang,” SainETIn: Jurnal Sains, Energi, Teknologi, dan Industri, vol. 4, no. 2, pp. 72–81, 2020. [2] Alghifari A., A. P. Putra, A. F. Pratama, and Sujito, “Analisis Pengujian Kualitas Tahanan Isolasi Pada Transformator Tegangan 150 kV Bay Gunung Sari 2 di Gardu Induk Waru,” Power Elektronik: Jurnal Orang Elektro, vol. 13, no. 1, pp. 22–25, 2024. [3] Muhammad A. F., U. Latifa, and I. A. Bangsa, “Analisis Isolasi Pada Generator Pembangkit Listrik Tenaga Air Saguling,” Power Elektronik: Jurnal Orang Elektro, vol. 10, no. 2, pp. 48–52, 2021. [4] Almanda D., and A. Ardiansyah, “Analisis Pengujian Tangen Delta Pada Bushing Trafo 150/20 Kv 60 Mva Di Gardu Induk Karet Lama,” RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer), vol. 5, no. 2, pp. 97–102, 2022. [5] Indral M. H., Y. Suzantry, and I. Priyadi, “Pengujian Tahanan Isolasi Pada Transformator Distribusi 160 kVA Di PT. PLN (PERSERO) UP3 Bengkulu,” Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer, vol. 12, no. 2, pp. 8–15, 2022. [6] Purba B., L. S. Patras, and N. M. Tulung, “Analisis Kemampuan Isolasi Transformator Berdasarkan Hasil Uji Indeks Polarisasi, Tangen Delta Dan Break Down Voltage,” 2023. [7] Tian X., and Y. Li, “Research on electrical characteristics of insulating silicone oil based on polarization-depolarization current method,” in 2020 IEEE 1st China International Youth Conference on Electrical Engineering (CIYCEE), IEEE, 2020, pp. 1–6. [8] Suganda S., and A. Muis, “Analisa Kualitas Tahanan Isolasi Transformator Daya,” SINUSOIDA, vol. 23, no. 2, pp. 1–10, 2021. [9] Rafiansyah M. A., and A. Wisaksono, “Analisis Uji Tahanan Isolasi Pada Power Transformator PT.PQR,” Jurnal Cakrawala Ilmiah, vol. 1, no. 11, pp. 2723–2732, 2022. [10] Yousof M. F. M., S. Al-Ameri, H. Ahmad, H. A. Illias, and S. N. M. Arshad, “A new approach for estimating insulation condition of field transformers using FRA,” Advances in Electrical and Computer Engineering, vol. 20, no. 1, pp. 35–42, 2020. [11] Robbani M. F., D. Nugroho, and G. Gunawan, “Penentuan kelayakan tahanan isolasi pada transformator 60 MVA di gardu induk 150 KV tegal dengan menggunakan indeks polarisasi, tangen delta, dan breakdown Voltage,” Elektrika, vol. 12, no. 2, pp. 60–66, 2020. [12] Situmeang U., B. Mulyanto, and M. P. Halilintar, “Analisis Kondisi Tahanan Isolasi Transformator Daya 125 MVA Menggunakan Indeks Polarisasi Tangen Delta dan Breakdown Voltage di PLTU Tenayan Raya 2 × 110 MW,” Jurnal Teknik Elektro Uniba (JTE UNIBA), vol. 6, no. 2, pp. 206–211, 2022. [13] Parvizi P., A. Mohammadi Amidi, M. Jalilian, and H. Parvizi, “A Mini Review of Insulation Testing Techniques for Power Cables in Transmission Lines,” Journal of Applied Dynamic Systems and Control, vol. 6, no. 1, pp. 88–95, 2023. [14] Suheta T., M. Z. A. Medjid, and K. Anwar, “Analisa Tahanan Isolasi Pada Transformator Daya 20 MVA Di Gardu Induk ULTG Ende,” Jurnal JEETech, vol. 5, no. 1, pp. 39–47, 2024. [15] Morsalin S., and B. T. Phung, “Dielectric response study of service-aged XLPE cable based on polarisation and depolarisation current method,” IEEE Transactions on Dielectrics and Electrical Insulation, vol. 27, no. 1, pp. 58–66, 2020. [16] Zhu G., K. Zhou, L. Lu, Y. Li, H. Xi, and Q. Zeng, “Online monitoring of power cables tangent delta based on low-frequency signal injection method,” IEEE Trans Instrum Meas, vol. 70, pp. 1–8, 2021. [17] Indra M. H., Y. S. Handayani, and I. Priyadi, “Pengujian Tahanan Isolasi Pada Transformator Distribusi 160 kVA Di PT. PLN (PERSERO) UP3 Bengkulu,” Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer, vol. 12, no. 2, pp. 8–15, 2022. [18] Prangkozolla G., “Uji Kelayakan Belitan Unit Auxiliary Transformer (UAT) PLTU Rembang,” Universitas Tidar, Magelang, 2021. [19] Hameed K. R., A. L. Suraiji, and A. O. Hanfesh, “Comparative the effect of distribution transformer coil shape on electromagnetic forces and their distribution using the FEM,” Open Engineering, vol. 14, no. 1, p. 20220503, 2024. [20] Bhalla D., R. B. Kumar, and H. O. Gupta, “Optimizing Relative Height of Transformer Windings for Least Electromagnetic Forces,” Int J Sci Res, vol. 8, no. 2, pp. 1217–1226, 2019. [21] Chang X., D. Chen, P. Zhao, and Y. Gao, “Research on Winding Dynamic Force and Displacement of Winding in Interturn Short Circuit of Stereo Roll Iron Core Transformer,” in Journal of Physics: Conference Series, IOP Publishing, 2024, p. 012103. [22] Rosyidi N., and D. R.Silitonga, “Analisis Pengukuran Transformator 400 kVA Menggunakan On Load Tap Changer,” SINUSOIDA, vol. 24, no. 1, pp. 1–8, 2022. [23] Kurniawan D., “Desain dan Implementasi Prototipe Solid State On-Load Tap Changer Pada Transformator Satu Fasa,” Institut Teknologi Sepuluh November, Surabaya, 2020. [24] Meliansyah P., and D. Aribowo, “Uji Tegangan Tembus Minyak on Load Tap Changer di Gardu Induk 150kv Rangkas Baru,” Ocean Engineering: Jurnal Ilmu Teknik dan Teknologi Maritim, vol. 1, no. 4, pp. 1–14, 2022. [25] Dai Q., Y. Liu, and G. Cheng, “Frequency domain spectroscopy for non-uniformly distributed moisture detection in transformer bushings,” IEEE Access, vol. 8, pp. 210429–210434, 2020. [26] Prihantiny R. S., D. Wahjudi, and P. Yulianto, “Pengaruh Kondisi Isolasi Dielektrik Terhadap Kehandalan Transformator Tenaga,” Teodolita: Media Komunkasi Ilmiah di Bidang Teknik, vol. 22, no. 2, pp. 81–94, 2021. [27] Sianturi R. A., “Pengujian Bushing Transformator Tenaga Studi Kasus Trafo 1 Gardu Induk Poncol Baru,” Universitas Tidar, Magelang, 2024. [28] Jeckson J., K. Fitriadi, and A. Ancolo, “Analisis Efisiensi Trafo Toroidal dan Trafo Inti Besi Pada Proses Pengisian Baterai Berbasis LabView,” Jurnal Ilmiah Teknik Elektro, vol. 5, no. 1, pp. 1–13, 2022. [29] Soni R., and B. Mehta, “Review on asset management of power transformer by diagnosing incipient faults and faults identification using various testing methodologies,” Eng Fail Anal, vol. 128, p. 105634, 2021. [30] Siburian J. M., J. Jumari, and T. M. B. Ulolo, “Studi Analisis Ketahanan Isolasi Pada Transformator di Gardu Induk Labuhan,” Jurnal Darma Agung, vol. 29, no. 3, pp. 499–510, 2021. [31] Prima G. A., Z. Anthony, A. Anugrah., “Analisa Tahanan Isolasi Pada Transformator Daya 150/30 Kv Gardu Induk Padang Luar PT PLN (PERSERO) Bukittinggi,” Indonesian Journal of Engineering and Technology (INAJET), vol. 6, no. 1, pp. 23–33, 2023. [32] Ababil K., “Analisa Perbandingan Kelayakan Tahanan Isolasi Transformator Daya Menggunakan Pengujian Indeks Polaritas, Tangen delta, Breakdown Voltage, dan Rasio Tegangan di Gardu Induk 150 kV Ulee Kareng,” Universitas Islam Negeri AR – Raniry, Banda Aceh, 2023. [33] Mahendra L. S., Z. Zulkifli, B. Herwono, Y. Anggraini, E. N. Sholikha, and K. Nisa, “Analisis Kondisi Belitan Stator Generator Melalui Pengujian Indeks Polarisasi dan Tan Delta (Dissipation Factor),” Jurnal Teknik Elektro dan Komputasi (ELKOM), vol. 5, no. 2, pp. 244–251, 2023. [34] Sutjipto R., H. Mukti, and K. E. Dzulfiqar, “Analisis Kondisi Isolasi Pada Station Service Transformer (SST),” Elposys: Jurnal Sistem Kelistrikan, vol. 11, no. 2, pp. 86–91, 2024. citation: Fadlika, Farhan (2025) ANALISIS PENGUJIAN KONDISI ISOLASI PADA BELITAN TAP CHANGER DAN BUSHING TRANSFORMATOR DI PT INDONESIA POWER SURALAYA. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa. document_url: https://eprints.untirta.ac.id/52584/1/FARHAN%20FADLIKA_3332200078_FULLTEXT.pdf document_url: https://eprints.untirta.ac.id/52584/2/FARHAN%20FADLIKA_3332200078_01.pdf document_url: https://eprints.untirta.ac.id/52584/3/FARHAN%20FADLIKA_3332200078_02.pdf document_url: https://eprints.untirta.ac.id/52584/4/FARHAN%20FADLIKA_3332200078_03.pdf document_url: https://eprints.untirta.ac.id/52584/5/FARHAN%20FADLIKA_3332200078_04.pdf document_url: https://eprints.untirta.ac.id/52584/6/FARHAN%20FADLIKA_3332200078_05.pdf document_url: https://eprints.untirta.ac.id/52584/7/FARHAN%20FADLIKA_3332200078_Ref.pdf document_url: https://eprints.untirta.ac.id/52584/8/FARHAN%20FADLIKA_3332200078_Lamp.pdf document_url: https://eprints.untirta.ac.id/52584/9/FARHAN%20FADLIKA_3332200078_CP.pdf