eprintid: 51694 rev_number: 21 eprint_status: archive userid: 16342 dir: disk0/00/05/16/94 datestamp: 2025-07-16 02:08:32 lastmod: 2025-07-16 02:08:32 status_changed: 2025-07-16 02:08:32 type: thesis metadata_visibility: show contact_email: 3332210057@untirta.ac.id creators_name: Randy, Eleanor creators_id: 3332210057 contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_name: HM, Hartono contributors_name: Felycia, Felycia contributors_id: 197601032002121003 contributors_id: 199202112022032013 corp_creators: Universitas Sultan Ageng Tirtayasa corp_creators: Fakultas Teknik corp_creators: Jurusan Teknik Elektro title: ANALISIS PENGARUH FILTER AKTIF TERHADAP LOSSES DAN DERATING PADA UNIT AUXILIARY TRANSFORMER AKIBAT BEBAN NON-LINIER DI PLTU SURALAYA UNIT 1 ispublished: pub subjects: T1 subjects: TK divisions: Elektro full_text_status: restricted keywords: Beban Non-linier, Harmonisa, Filter Aktif Paralel, Losses, Derating abstract: Akibat dari penggunaan beban non-linier adalah timbulnya harmonisa. Transformator UAT (Unit Auxiliary Transformer) merupakan salah satu peralatan utama pada PT. Indonesia Power PLTU Suralaya unit 1 yang secara langsung merasakan efek negatif dari harmonisa karena terhubung langsung oleh beban non-linier berupa rectifier. Penelitian ini bertujuan untuk menganalisis kualitas daya listrik yang dipengaruhi oleh harmonisa akibat pengoperasian beban non-linier dan menganalisis besarnya losses serta derating yang dapat mempengaruhi kinerja transformator UAT 1600 kVA. Filter aktif paralel dengan kontrol PI dirancang dengan menggunakan software Matlab R2018b, agar dapat mereduksi harmonisa, memperkecil losses, dan meningkatkan kapasitas kerja transformator UAT 1600 kVA. Hasil penelitian menunjukkan bahwa sebelum pemasangan filter aktif diperoleh THDi pada fasa R sebesar 22,51%, fasa S sebesar 21,67%, dan fasa T sebesar 27,89%. Selanjutnya setelah pemasangan filter aktif paralel pada sistem dapat mereduksi THDi secara signifikan hingga sesuai standar IEEE 519-2014, yaitu menjadi 1,2% pada fasa R, 1,09% pada fasa S, dan 0,51% pada fasa T. Hasil perhitungan sebelum pemasangan filter aktif nilai total losses akibat harmonisa diperoleh sebesar 136,28 kW dan derating transformator 1600 kVA sebesar 11,32% atau setara dengan 182 kVA. Setelah filter aktif terpasang terjadi penurunan pada nilai total losses menjadi 38,38 kW dan derating transformator 1600 kVA menjadi 0,026% atau sebesar 500 VA. date: 2025-07 date_type: published pages: 98 institution: Fakultas Teknik Universitas Sultan Ageng Tirtayasa department: Jurusan Teknik Elektro thesis_type: sarjana thesis_name: sarjana official_url: https://eprints.untirta.ac.id/ referencetext: [1] M. A. Alafghani, “Pemantauan dan Assesmen Kualitas Daya pada Gedung Pemerintah Studi Kasus di Gedung PPSDM KEBTKE,” INNOVATIVE: Journal Of Social Science Research, vol. 3, no. 6, hlm. 397–408, 2023. [2] P. Nugraha, Made Dika, Kadek Agus, Nyoman A, “( SVC ) to Reduce Total Harmonic Distortion ( THD ) in Bali Transmission System,” Teknik Elektro dan Komputer, vol. 12, no. 2, hlm. 139–144, 2023. [3] N. F. Ibrahim, M. M. Mahmoud, A. I. Omar, dan H. Abdelfattah, “Operation of Grid-Connected PV System With ANN-Based MPPT and an Optimized LCL Filter Using GRG Algorithm for Enhanced Power Quality,” IEEE Access, vol. 11, no. October, hlm. 106859–106876, 2023, doi: 10.1109/ACCESS.2023.3317980. [4] H. Setiawan, B. Y. Dewantara, dan I. Winarno, “Eliminasi Harmonisa Pada Induction Furnace Menggunakan Filter Hybrid,” Jurnal Teknik Elektro dan Informatika, vol. 19, no. 1, hlm. 116–126, 2024, doi: 10.30587/e-link.v19i1.7219. [5] B. Davira dan K. Karim, “Analisis Kualitas Daya Listrik Gedung Direktorat Politeknik Negeri Samarinda,” PoliGrid, vol. 5, no. 1, hlm. 1–12, 2024, doi: 10.46964/poligrid.v5i1.20. [6] A. Zulkarnaini, R. Sinambela, L. Lisapaly, dan M. Manik, “Analisis Pengukuran Harmonisa Tegangan Dan Arus Listrik Di Gedung Administrasi Universitas Jayabaya,” Transmisi: Jurnal Ilmiah Teknik Elektro, vol. 26, no. 3, hlm. 132–138, 2024, doi: 10.14710/transmisi.26.3.132-138. [7] K. Kritsanasuwan, U. Leeton, dan T. Kulworawanichpong, “Harmonic mitigation of AC electric railway power feeding system by using single-tuned passive filters,” Energy Reports, vol. 8, no. 10, hlm. 1116–1124, 2022, doi: 10.1016/j.egyr.2022.05.276. [8] R. Boopathi dan V. Indragandhi, “Comparative analysis of control techniques using a PV-based SAPF integrated grid system to enhance power quality,” e-Prime - Advances in Electrical Engineering, Electronics and Energy, vol. 5, Sep 2023, doi: 10.1016/j.prime.2023.100222. [9] M. L. Duc, P. Bilik, dan R. Martinek, “Harmonics Signal Feature Extraction Techniques: A Review,” Mathematics, vol. 11, no. 8, hlm. 1–36, 2023, doi: 10.3390/math11081877. [10] N. Dwi Septiawan dkk., “Analisis Kualitas Daya Listrik Di Gedung A Fakultas Sains Dan Teknologi Universitas Jambi,” Jurnal Sistem Informasi dan Ilmu Komputer, vol. 2, no. 1, hlm. 37–48, 2024, doi: 10.59581/jusiik-widyakarya.v2i1.2197. [11] E. Faustina, E. Openg, B. Widodo, dan R. Purba, “Analisa Harmonisa Pembangkit Listrik Tenaga Surya ( PLTS ) Off – Grid 290 Wp Dengan Kombinasi Beban Linier Dan Non Linier di Gedung Fakultas Teknik UKI – Jakarta Menggunakan Matlab Simulink,” Jurnal Ilmiah Program Studi Teknik Elektro, vol. 7, no. 1, hlm. 1–13, 2024, doi: 10.33541/lektrokom.v7i1.5658. [12] W. A. A. Salem, W. Gabr Ibrahim, A. M. Abdelsadek, dan A. A. Nafeh, “Grid connected photovoltaic system impression on power quality of low voltage distribution system,” Cogent Eng, vol. 9, no. 1, 2022, doi: 10.1080/23311916.2022.2044576. [13] D. Committee, I. Power, dan E. Society, “IEEE Std 519-2014,” New York, 2014. doi: 10.1109/IEEESTD.2014.6826459. [14] M. S. Seddik, M. B. Eteiba, dan J. Shazly, “Evaluating the Harmonic Effects on the Thermal Performance of a Power Transformer,” Energies (Basel), vol. 17, no. 19, hlm. 1–17, Okt 2024, doi: 10.3390/en17194871. [15] R. Sutjipto dan Wijaya Kusuma, “Analisis Pengaruh Harmonisa Terhadap Losses Transformator 500kVA,” ELPOSYS: Jurnal Sistem Kelistrikan, vol. 9, no. 2, hlm. 13–18, 2022, doi: 10.33795/elposys.v9i2.134. [16] Y. Chusna Arif, “Implementation Of Hybrid Filter For Harmonics Reduction In Non-Linear Loads,” Eduvest - Journal of Universal Studies, vol. 3, no. 2, hlm. 465–476, 2023, doi: 10.59188/eduvest.v3i2.751. [17] B. Park, J. Lee, H. Yoo, dan G. Jang, “Harmonic mitigation using passive harmonic filters: Case study in a steel mill power system,” Energies (Basel), vol. 14, no. 8, hlm. 1–16, 2021, doi: 10.3390/en14082278. [18] A. A. Imam, R. Sreerama Kumar, dan Y. A. Al-Turki, “Modeling and simulation of a pi controlled shunt active power filter for power quality enhancement based on p-q theory,” Electronics (Switzerland), vol. 9, no. 4, hlm. 1–17, Apr 2020, doi: 10.3390/electronics9040637. [19] Z. L. Hormat Ferdinto Situmorang, Pristisal Wibowo, “Analisis Penggunaan Kapasitor Bank Dalam Upaya Perbaikan Faktor Daya Pada Low Voltage Main Distribution Panel (LVMDP) Di PT. Permata Hijau Palm Oleo (PHPO) KIM II,” Journal of Information Technology and Computer Science (INTECOMS), vol. 7, no. 3, hlm. 990–1001, 2024, doi: 10.31539/intecoms.v7i3.10813. [20] I. M. A. Y, A. Zamzami, F. H. Jufri, dan F. Husnayain, “Studi Harmonisa Akibat Komponen Penyearah pada Gardu Traksi Kereta Rel Listrik ( KRL ),” CYCLOTRON, vol. 3, no. 2, hlm. 1–6, 2020, doi: 10.30651/cl.v3i2.5570. [21] D. Monika, L. Gumilar, dan S. N. Rumokoy, “Analisa Mutu Daya Sistem Generator Tenaga Listrik Terhadap Pemakaian Beban Non Linear Berbasis IOT,” Jurnal Teknik Elektro, vol. 13, no. 1, hlm. 41–50, 2023, doi: 10.36546/jte.v13i1.897. [22] M. E. Hutagalung, I. M. W. Kastawan, dan A. Pudin, “Analisis Karakteristik Harmonisa Pada Sistem Elektrikal Pembangkit Listrik Tenaga Gas dan Uap ( PLTGU ) Tambak Lorok Blok 2,” Energi, vol. 12, no. 2, hlm. 40–50, Nov 2023, doi: 10.35313/.v12i2.5250. [23] R. B. Nugraha, I. M. W. Kastawan, dan P. Raharjo, “Pengaruh carrier frequency VSD terhadap harmonisa suplai daya listrik motor induksi 3-fasa,” JITEL (Jurnal Ilmiah Telekomunikasi, Elektronika, dan Listrik Tenaga), vol. 3, no. 2, hlm. 121–126, 2023, doi: 10.35313/jitel.v3.i2.2023.121-126. [24] E. Dermawan dan R. L. Rahman, “Analisis Pengaruh Distorsi Harmonisa terhadap Deviasi Pengukuran Energi Listrik pada kWh Meter,” Jurnal Elektrum, vol. 15, no. 2, hlm. 7–16, 2018. [25] F. Yurliandri, “Aplikasi Filter Pasif Sebagai Pereduksi Gelombang Cacat Akibat Pemakaian Beban Non Linier,” MSI Transaction on Education, vol. 3, no. 1, hlm. 1–14, 2022, doi: 10.46574/mted.v3i1.73. [26] D. Roger C. dan M. F. Mc Granaghan, Electrical Power Systems Quality, Second Edition. New York, 2004. [27] A. A. G. Kresna Dharma Yudha, Cok. G. Indra Partha, dan I. W. Sukerayasa, “Simulasi Penggunaan Filter Aktif Shunt Dengan Kontrol Pi Untuk Meredam Total Harmonic Distortion (Thd) Pada Gedung Dh Teknik Elektro Universitas Udayana,” Jurnal SPEKTRUM, vol. 10, no. 4, hlm. 143–151, 2023, doi: 10.24843/spektrum.2023.v10.i04.p18. [28] A. M. Syabani, I. M. W. Kastawan, S. Saodah, dan K. Kunci, “Rancang Inverter 5-Level Cascaded H-Bridge untuk PLTS On Grid dengan Kapasitas Beban 25 kW,” Jurnal Energi, vol. 11, no. 2, hlm. 12–17, Apr 2022, doi: 10.35313/energi.v11i2.3533. [29] D. A. N. Farizi, I. G. N. Satriyadi, dan I. M. Y. Negara, “Analisis Harmonisa dan Rnancang Filter Single Tuned pada Transfomator Distribusi 1250 kVA di PT. Industri Kereta Api (Persero),” Jurnal Teknik ITS, vol. 13, no. 1, hlm. 28–33, 2024, doi: 10.12962/j23373539.v13i1.144958. [30] Aini Zulfatri dan Mar’i Aqil, Desain Single Tuned Filter Terhadap Harmonisa pada Transformator Distribusi, 1 ed. Pekan Baru: Al-Mujtahadah Press, 2021. [31] Sanjay Kulshreshtha dan Dr D.K Chaturvedi, “Effect of Generated Harmonics On Transformer Losses Due to Solar Penetration,” International Research Journal on Advanced Engineering and Management (IRJAEM), vol. 2, no. 06, hlm. 1939–1945, Jun 2024, doi: 10.47392/irjaem.2024.0287. [32] IEEE Std C57.110TM-2018 (Revision of IEEE Std C57.110-2008), “IEEE Recommended Practice for Establishing Liquid Immersed and Dry-Type Power and Distribution Transformer Capability when Supplying Nonsinusoidal Load Currents,” hlm. 1–68, Okt 2018, doi: 10.1109/IEEESTD.2018.8511103. [33] I. Wayan Sutama, “Dampak Beban Non Linier Terhadap Penurunan Kapasitas Transformator Distribusi DI Penyulang Wibrata,” SINTESA, 2023, hlm. 549–556. [34] M. Apryansyah dan M. K. Iwa Garniwa, “Effect of K-Factor on Capability in Power Transformers,” dalam Journal of Physics: Conference Series, IOP Publishing Ltd, Jul 2021, hlm. 1–12. doi: 10.1088/1742-6596/1962/1/012005. [35] Y. Fernando, I. G. A. Darmawan, dan N. U. Putri, “Analisis Penyempurnaan Nilai Harmonisa Pada Gardu Traksi Kereta Rel Listrik ( KRL ) Jalur Pesing – Duri Menggunakan Filter Pasif,” ELECTRICIAN – Jurnal Rekayasa dan Teknologi Elektro Analisis, vol. 18, no. 02, hlm. 113–120, 2024, doi: 10.23960/elc.v18n2.2560. [36] I. W. Farhan Muhammad, “Eliminasi Harmonisa pada Doubly-Fed Induction Generator Menggunakan Filter Pasif,” Teknik Elektro dan Informatika, vol. 17, no. 1, hlm. 13–27, 2022, doi: 10.30587/e-link.v17i1.2947. [37] H. Hingol, V. Deshpande, dan A. V. Sant, “Modified symmetrical sinusoidal integrator and instantaneous reactive power theory-based control of shunt active filter,” Energy Reports, vol. 8, hlm. 515–523, 2022, doi: 10.1016/j.egyr.2022.08.151. [38] M. Popescu, A. Bitoleanu, C. V. Suru, M. Linca, dan L. Alboteanu, “Shunt Active Power Filters in Three-Phase, Three-Wire Systems: A Topical Review,” 11 Juni 2024, Multidisciplinary Digital Publishing Institute (MDPI). doi: 10.3390/en17122867. [39] P. Kumar Barik dkk., “A novel negative feedback phase locked loop-based reference current generation technique for shunt active power filter,” International Journal of Electrical Power and Energy Systems, vol. 153, Nov 2023, doi: 10.1016/j.ijepes.2023.109389. [40] H. Ghanayem, M. Alathamneh, X. Yang, S. Seo, dan R. M. Nelms, “Enhanced Three-Phase Shunt Active Power Filter Utilizing an Adaptive Frequency Proportional-Integral–Resonant Controller and a Sensorless Voltage Method,” Energies (Basel), vol. 18, no. 1, hlm. 1–17, Jan 2025, doi: 10.3390/en18010116. [41] A. Ulinuha dan E. M. Sari, “The influence of harmonic distortion on losses and efficiency of three-phase distribution transformer,” J Phys Conf Ser, vol. 1858, hlm. 1–10, 2021, doi: 10.1088/1742-6596/1858/1/012084. citation: Randy, Eleanor (2025) ANALISIS PENGARUH FILTER AKTIF TERHADAP LOSSES DAN DERATING PADA UNIT AUXILIARY TRANSFORMER AKIBAT BEBAN NON-LINIER DI PLTU SURALAYA UNIT 1. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa. document_url: https://eprints.untirta.ac.id/51694/1/Randy%20Eleanor_3332210057_Fulltext.pdf document_url: https://eprints.untirta.ac.id/51694/2/Randy%20Eleanor_3332210057_01.pdf document_url: https://eprints.untirta.ac.id/51694/3/Randy%20Eleanor_3332210057_02.pdf document_url: https://eprints.untirta.ac.id/51694/4/Randy%20Eleanor_3332210057_03.pdf document_url: https://eprints.untirta.ac.id/51694/5/Randy%20Eleanor_3332210057_04.pdf document_url: https://eprints.untirta.ac.id/51694/6/Randy%20Eleanor_3332210057_05.pdf document_url: https://eprints.untirta.ac.id/51694/7/Randy%20Eleanor_3332210057_Ref.pdf document_url: https://eprints.untirta.ac.id/51694/8/Randy%20Eleanor_3332210057_Lamp.pdf document_url: https://eprints.untirta.ac.id/51694/9/Randy%20Eleanor_3332210057_CP.pdf