eprintid: 51219 rev_number: 17 eprint_status: archive userid: 14486 dir: disk0/00/05/12/19 datestamp: 2025-07-11 03:27:30 lastmod: 2025-07-11 03:27:30 status_changed: 2025-07-11 03:27:30 type: thesis metadata_visibility: show contact_email: alkautsarcahyadi26@gmail.com creators_name: Cahyadi, Muhammad Tegar Alkausar creators_id: 3332210073 contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_name: Otong, Muhammad contributors_name: Felycia, Felycia contributors_id: 197203192005011001 contributors_id: 199202112022032013 corp_creators: Universitas Sultan Ageng Tirtayasa corp_creators: Fakultas Teknik corp_creators: Teknik Elektro title: Analisis Penggunaan Station Service Transformer (SST) Pada Proses Start Up dan Backup UST Unit 3-4 PLTU Suralaya ispublished: pub subjects: TK divisions: Elektro full_text_status: restricted keywords: Pemakaian Sendiri, SST, Start Up abstract: PLTU Suralaya menggunakan dua trafo drop voltage, yaitu Unit Service Transformer (UST) dan Station Service Transformer (SST), di mana SST berfungsi pada saat start up awal generator. Ketika generator mencapai minimal 10% dari daya nominalnya, suplai daya dialihkan dari SST ke UST. Proses start up pada Pembangkit Listrik Tenaga Uap (PLTU) melibatkan pengoperasian peralatan utama seperti sistem pengisian air, supply bahan bakar, dan peningkatan tekanan serta temperatur uap. Sistem pemakaian sendiri (auxiliary) memegang peran krusial dalam menunjang produksi energi listrik, dengan beban auxiliary yang mengkonsumsi daya hingga 10% dari total daya pembangkitan. Penelitian ini mengusulkan penggunaan SST sebagai cadangan untuk memastikan kontinuitas pasokan energi listrik saat UST mengalami kerusakan. Dengan sistem ini, SST dapat mengambil alih fungsi UST untuk mensuplai beban auxiliary, sehingga unit pembangkitan tetap beroperasi meskipun UST tidak berfungsi. Hasil penelitian menunjukkan bahwa optimasi SST pada PLTU Suralaya mampu memasok daya ke unit pembangkitan tanpa memicu gangguan overcurrent, over voltage, atau under voltage. Hal ini tercapai dengan nilai arus total, persentase tegangan, dan daya semu pada busbar yang tetap sesuai batas operasional SOP saat start up beban. Selain itu, analisis komparatif skenario sistem backup menghasilkan rugi-rugi daya yang lebih rendah (0,118 MW) dibandingkan kondisi normal (0,143 MW), membuktikan efektivitas SST dalam meminimalkan kerugian energi. Penelitian ini bertujuan untuk memberikan solusi efektif dalam meminimalkan downtime dan meningkatkan keandalan sistem pembangkitan di PLTU Suralaya. date: 2025-06-03 date_type: published pages: 93 institution: Fakultas Teknik Universitas Sultan Ageng Tirtayasa department: Teknik Elektro thesis_type: sarjana thesis_name: sarjana referencetext: [1] M. Farhan, R. Hidayat, and Y. Saragih, “Pengaruh Pembebanan Terhadap Arus Eksitasi Generator Unit 2 PLTMH Curug,” Jurnal Simetrik, vol. 1, no. 1, Jun. 2021. [2] A. Rully Muzani, N. Safitri, P. Studi Teknologi Rekayasa Pembangkit Energi Jurusan Teknik Elektro, and P. Negeri Lhokseumawe, “Analisa Konsumsi Energi Listrik Pemakaian Sendiri Unit Satu pada PLTU Nagan Raya,” JURNAL TEKTRO, vol. 7, no. 2, 2023. [3] Y. Yulisman and F. Rahman, “Analisis Kontingensi pada Sistem Pemakaian Sendiri PLTU Ombilin,” Journal of Electrical Power Control and Automation (JEPCA), vol. 5, no. 1, p. 24, Jun. 2022, doi: 10.33087/jepca.v5i1.66. [4] A. S. Sampeallo, P. J. Fischer, and J. Teknik Elektro, “Analisis Gangguan Hubung Singkat Pada Jaringan Pemakaian Sendiri PLTU Bolok PT. SMSE (IPP) Unit 3 dan 4 Menggunakan Software ETAP 12.6.0,” Jurnal Media Elektro, vol. VIII, no. 1, Apr. 2019. [5] R. Alfanz, R. A. Zhalifunnas, A. Umyati, L. Herlina, and R. Fahrizal, “Pengenalan dan Implementasi Sistem Proteksi Motor Induksi pada Industri Pembangkit Listrik di Kota Cilegon Article history,” Jurnal Pengabdian Pada Masyarakat (ELDIMAS), vol. 2, no. 1, pp. 30–41, May 2024, doi: 10.37905/ejppm.v2i1. [6] V. Ivanova, N. Rozhentcova, E. Gracheva, and A. Udaratin, “Development of an automated control system for 6/0.4 kV transformer substation with automatic transfer switch using standard IEC 61131-3,” in E3S Web of Conferences, EDP Sciences, Jul. 2021. doi: 10.1051/e3sconf/202128801105. [7] PT. Indonesia Power UBP Suralaya, “Data Fault UST Unit 1-4,” 2020. [8] W. Firman Maulana, “Perhitungan hasil uji Tangen Delta sebagai parameter kelayakan Transformator pada Gardu Induk Rungkut 150 kV 8,” Jurnal Teknik Elektro, vol. 14, no. 1, 2024. [9] L. Nurul Syamsy, T. Tohir, and Supriyanto, “Analisis Gangguan Hubung Singkat Penyulang RASA PT. PLN (Persero) UP3 Majalaya Menggunakan Software ETAP,” Prosiding Industrial Research Workshop and National Seminar, vol. 15, pp. 378–255, Jul. 2024. [10] R. Sutjipto, H. K. Mukti, and K. Eka Dzulfiqar, “Analisis Kondisi Isolasi Pada Station Service Transformer (SST),” ELPOSYS :Jurnal Sistem Kelistrikan, Jun. 2024. [11] H. Zulkarnain and M. Simanjuntak, “Resistivitas dan Indeks Polarisasi Minyak Transformator Bekas Dengan Penambahan Nanopartikel ZnO dan Al2O3,” Prosiding Seminar Nasional Teknik UISU (SEMNASTEK), vol. 6, pp. 129–133, 2023. [12] A. Mujanović, T. Konjić, and A. Dedić, “Electricity Efficiency of Auxiliary Power Systems in Coal Thermal Power Plant,” International Journal of Electrical and Computer Engineering Systems, vol. 11, no. 2, pp. 101–110, 2020. [13] R. Gianto, “Model Tegangan Konstan dari Pembangkit Listrik Tenaga Angin Kecepatan Variabel yang Berbasis SCIG Untuk Analisis Aliran Daya,” Jurnal Rekayasa dan Teknologi Elektro, vol. 18, no. 1, pp. 82–88, 2024. [14] E. C. Sihite, N. Desryanto, and B. A. Prawiraatmaja, “Analisis Aliran Daya Terminal Internasional Bandar Udara Internasional I Gusti Ngurah Rai Menggunakan ETAP 19.0.1,” Jurnal Review Pendidikan dan Pengajaran (JRPP), vol. 7, pp. 4219–4226, 2024. [15] M. Buang, “Aplikasi Peralatan Flexible AC transmission Systems (FACTS) Pada Sistem Tenaga Listrik,” JNSTA ADPERTISI JOURNAL, vol. 4, no. 1, pp. 1–10, 2023, [Online]. Available: http://jurnal.adpertisi.or.id/index.php/JNSTA [16] A. Sarwati Rahmat and A. Hafid, “Simulasi Sistem Monitoring Kondisi Operasi Sistem Energi Elektrik (SEE) Berbasiskan Metode Per Unit Dengan Menggunakan Perangkat Lunak PSCAD,” Ainet : Jurnal Informatika, vol. 3, no. 2, pp. 53–66, 2021. [17] H. F. Yono, NJ. Thamrin, and V. Yusiana, “Studi Aliran Daya pada PT. PLN (Persero) UIWS2JB UP3 Jambi ULP Kotabaru Penyulang Palem dengan Menggunakan Software Electric Transient and Analysis Program (ETAP),” Journal of Electrical Power Control and Automation (JEPCA), vol. 7, no. 1, p. 13, Sep. 2024, doi: 10.33087/jepca.v7i1.112. [18] K. M. Pangloli, S. Thaha, and H. A. Gaffar, “Analisis Aliran Daya Menggunakan Metode Fast Decoupled Pada Sisi Tegangan 6.3 KV PT. Semen Tonasa V,” 2020. [19] I. Ismail, F. Eka Putra Surusa, and S. Humena, “Analysis of the Power Flow on the Electricity Gorontalo System Due to the Entry of 150 KV Industrial Customers,” Jambura Journal of Electrical and Electronics Engineering, vol. 6, no. 2, 2024. [20] N. Gama, F. Lisi, M. Tuegeh, and A. F. Nelwan, “Aliran Daya Optimal Pada Sistem Minahasa,” Jurnal Teknik Elektro dan Komputer, vol. 1, no. 1, pp. 1–10, 2022. [21] R. K. Putra, M. Daud, A. Setiawan, and A. Hasibuan, “Penetration Impact of Distributed Generation of Wind Turbines on PLN’s Electric Distribution Network at Krueng Raya Aceh Besar,” MOTIVECTION : Journal of Mechanical, Electrical and Industrial Engineering, vol. 5, no. 2, pp. 245–260, Mar. 2023, doi: 10.46574/motivection.v5i2.214. [22] W. P. Guamán, G. N. Pesántez, X. A. Proaño, E. M. Pérez, and W. V. Tigse, “Power Flow Solution Combining Newton-Raphson and Fast Decoupled Methods,” in Advances in Intelligent Systems and Computing, Springer Science and Business Media Deutschland GmbH, 2021, pp. 222–233. doi: 10.1007/978-3-030-60467-7_19. [23] M. A. F. Haurissa, “Simulasi Aliran Daya Berbasis ETAP Menggunakan Metode Newton-Raphson Pada Jaringan Distribusi 20KV Penyulang Lateri 2 dan Lateri 3,” ELKO, vol. 4, no. 1, pp. 360–68, Jun. 2023. [24] D. Abdullah and Badaruddin, “Analisa Perbaikan Penampang Penghantar Guna Mengurangi Drop Tegangan dan Simulasi ETAP 16.0 Pada JTR GD KRDB di Wilayah Kerja PT. PLN (Persero) ULP Serang Kota,” Jurnal Teknologi Elektro, Universitas Mercu Buana, vol. 11, no. 1, Jan. 2020. [25] A. Imran and N. A. D. Nayla, Aplikasi Sistem Tenaga Listrik. Purbalingga: EUREKA MEDIA AKSARA, 2024. [26] A. Mujanović, T. Konjić, and A. Dedić, “Electricity Efficiency of Auxiliary Power Systems in Coal Thermal Power Plant,” International Journal of Electrical and Computer Engineering Systems, vol. 11, no. 2, pp. 101–110, 2020, doi: 10.32985/IJECES.11.2.5. [27] R. Afrianda, “Optimasi Pemakaian Sendiri PLTU dengan Metode Audit Energi pada Motor Listrik 3 Fasa di PLTU X,” Jurnal Ilmiah Setrum Article In Press, vol. 9, no. 2, pp. 63–73, 2020. [28] K. M. Pangloli, S. Thaha, and H. A. Gaffar, “Analisis Aliran Daya Menggunakan Metode Fast Decoupled Pada Sisi Tegangan 6.3 KV PT. Semen Tonasa V,” in Prosiding Seminar Nasional Teknik Elektro dan Informatika (SNTEI), Makassar, Oct. 2020, pp. 8–14. [29] H. An Nuur Muhammad and A. Asri, “Analisis Kontingensi Sistem Tenaga Listrik Dengan Metode Fast Decoupled Untuk Menghitung Aliran Daya Di Gardu Induk Tello,” Journal of Power Energy System, vol. 1, no. 01, pp. 1–9, Apr. 2023, [Online]. Available: https://doi.org/xxx [30] V. Ravikumar, S. Ranjith, and T. Bhavyasree, “Automatic Load Sharing of Distribution Transformers to Reduce Over all Losses in Distribution network,” in E3S Web of Conferences, EDP Sciences, Oct. 2021. doi: 10.1051/e3sconf/202130901126. [31] PT. Indonesia Power UBP Suralaya, “Data Specifications Auxiliary Unit 3-4,” Cilegon, 2024. citation: Cahyadi, Muhammad Tegar Alkausar (2025) Analisis Penggunaan Station Service Transformer (SST) Pada Proses Start Up dan Backup UST Unit 3-4 PLTU Suralaya. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa. document_url: https://eprints.untirta.ac.id/51219/1/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_Fulltext.pdf document_url: https://eprints.untirta.ac.id/51219/2/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_01.pdf document_url: https://eprints.untirta.ac.id/51219/3/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_02.pdf document_url: https://eprints.untirta.ac.id/51219/4/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_03.pdf document_url: https://eprints.untirta.ac.id/51219/5/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_04.pdf document_url: https://eprints.untirta.ac.id/51219/6/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_05.pdf document_url: https://eprints.untirta.ac.id/51219/7/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_Ref.pdf document_url: https://eprints.untirta.ac.id/51219/8/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_Lamp.pdf document_url: https://eprints.untirta.ac.id/51219/9/Muhammad%20Tegar%20Alkausar%20Cahyadi_3332210073_CP.pdf