ANALISA GANGGUAN PETIR AKIBAT SAMBARAN LANGSUNG PADA SALURAN TRANSMISI TEGANGAN TINGGI MENGGUNAKAN METODE EMPIRIS

SAEFUL MUNAJAT, MUHAEDI (2013) ANALISA GANGGUAN PETIR AKIBAT SAMBARAN LANGSUNG PADA SALURAN TRANSMISI TEGANGAN TINGGI MENGGUNAKAN METODE EMPIRIS. S1 thesis, Fakultas teknik universitas sultan ageng tirtayasa.

[img] Text (fulltext)
Skripsi Analisa Gangguan Petir T Elektro 2013 (1)_compressed.pdf
Restricted to Registered users only

Download (5MB)

Abstract

Salah satu penyehab yang dapat mengakibatkan terganggunya penyaluran cnergi listrik ialah gangguan akibat sambaran langsung. Pada penelitian ini akan dibahas gangguan akibat sambaran petir langsung yang terdiri dari dua macam, yaitu sambaran pada kawat tanah dan sambaran pada kawat fasa (shielding failure). Besaran yang menggambarkan sifat kerja saluran transmisi terhadap petir dinyatakan dalam jumlah gangguan per satuan panjang per tahun (gangguan/100 km/tahun, metode penentuan kinerja kilat saluran transmisi disebut dengan metode tegangan empiris. tinggi Sebagai 150kV acuan untuk menghitung sifat kerja saluran transmisi digunakan data sekunder dari PT.PLN Gardu induk Cilegon gangguan lama spesifik dan data sekunder dari Stasiun BMKG Serang - Banten. Angka oleh Shielding Lighting Performance merupakan gangguan yang disebabkan gangguan total disebabkan Failure dan Back Flashover, dari hasil perhitungan jumlah gangguan per 100 oleh Shielding Failure dan Back Flashover 10,47 fasa R sebesar 16°, km fasa per tahun, dan hasil sudut perlindungan efektif pada kawat S sebesar 7,8°, fasa T sebesar 5,4°.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
Thesis advisorAlimuddin, Alimuddin197204172008121004
Thesis advisorHerudin, Herudin197910252006041002
Additional Information: One of the cause that can cause problem electricity energy canalization direct stroke consequence disturbance. in this watchfulness be discussed direct thunder stroke consequence disturbance that consists of two kinds, that is strike in soil wire and strike in wire fasa (shielding failure). that describe transmission channel work character towards thunder is declared in number disturbance per long unit per year (disturbance/100 km/year, transmission channel lightning performance determination method is called with empirical method. As reference to count high voltage transmission channel work character 150kV used secondary data from pt. PLN mother guardhouse Cilegon long and secondary data from station BMKG Serang - Banten. specific disturbance number lighting performance be disturbance that caused by shielding failure and back flashover, from total disturbance tally result is caused by shielding failure and back flashover 10,47 disturbance per 100 km per year and effective protection corner result in wire fasa r as big as 16°, fasa s as big as 7,8°, fasa t as big as 5,40.
Uncontrolled Keywords: Sambaran langsung, Shielding Failure, Back Flashover, Sudut perlindungan efektif
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: 03-Fakultas Teknik > 20201-Jurusan Teknik Elektro
Depositing User: SISWA MAGANG FT
Date Deposited: 18 Sep 2025 02:53
Last Modified: 18 Sep 2025 02:53
URI: http://eprints.untirta.ac.id/id/eprint/54753

Actions (login required)

View Item View Item