RAYFADLI, ZIDAN (2024) ANALISIS POTENSI PENINGKATAN EFISIENSI ENERGI DI GEDUNG CENTER OF EXCELLENCE (COE) FAKULTAS TEKNIK UNTIRTA. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa.
Text (Full text)
Zidan Rayfadli_3331200030_Fulltext.pdf Restricted to Registered users only Download (3MB) | Request a copy |
|
Text (Bab 1)
Zidan Rayfadli_3331200030_01.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text (Bab 2)
Zidan Rayfadli_3331200030_02.pdf Restricted to Registered users only Download (746kB) | Request a copy |
|
Text (Bab 3)
Zidan Rayfadli_3331200030_03.pdf Restricted to Registered users only Download (338kB) | Request a copy |
|
Text (Bab 4)
Zidan Rayfadli_3331200030_04.pdf Restricted to Registered users only Download (937kB) | Request a copy |
|
Text (Bab 5)
Zidan Rayfadli_3331200030_05.pdf Restricted to Registered users only Download (9kB) | Request a copy |
|
Text (Daftar Referensi)
Zidan Rayfadli_3331200030_Ref.pdf Restricted to Registered users only Download (426kB) | Request a copy |
|
Text (Daftar Lampiran)
Zidan Rayfadli_3331200030_Lamp.pdf Restricted to Registered users only Download (682kB) | Request a copy |
|
Text (Cek Plagiasi)
Zidan Rayfadli_3331200030_CP.pdf Restricted to Registered users only Download (14MB) | Request a copy |
Abstract
Referring to the Regulation of the Ministry of Energy and Mineral Resources Government Number 14 of 2012 on Energy Management, it explains that an energy audit is a process of evaluating energy utilization and identifying energy-saving opportunities as well as recommending efficiency improvements for energy source users and energy users in the context of energy conservation. This research was conducted at the Center of Excellence Building, Faculty of Engineering, Sultan Ageng Tirtayasa University, with the aim of determining the Building Energy Consumption Intensity (IKE) and analyzing the potential for electrical energy use efficiency. The research was conducted by measuring light intensity and observing the condition of the lighting system to standardize whether the lighting system in a room complies with SNI. Additionally, the air conditioning system was also calculated by observing the building structure and various factors that could be sources of heat in the room. From the results of the observation, a cooling load calculation was performed using the CLTD method. Based on the obtained data, there is an opportunity for energy savings from the use of lighting, air conditioning, and elevator systems amounting to 42,639.05 kWh/year or approximately 18% of the installed system.
Item Type: | Thesis (S1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
|||||||||
Uncontrolled Keywords: | Audit Energi, IKE, Sistem Pencahayaan, Sistem Tata Udara, Metode CLTD. | |||||||||
Subjects: | T Technology > TJ Mechanical engineering and machinery | |||||||||
Divisions: | 03-Fakultas Teknik > 21201-Jurusan Teknik Mesin | |||||||||
Depositing User: | Zidan Rayfadli | |||||||||
Date Deposited: | 05 Dec 2024 15:22 | |||||||||
Last Modified: | 05 Dec 2024 15:22 | |||||||||
URI: | http://eprints.untirta.ac.id/id/eprint/44236 |