Search for collections on EPrints Repository UNTIRTA

PENGUJIAN HEAD LOSS PADA SISTEM PEMIPAAN SISTEM PENGENDALIAN LEVEL AIR SKALA LABORATORIUM

DONO RAMDHANI, EKO (2017) PENGUJIAN HEAD LOSS PADA SISTEM PEMIPAAN SISTEM PENGENDALIAN LEVEL AIR SKALA LABORATORIUM. S1 thesis, UNIVERSITAS SULTAN AGENG TIRTAYASA.

[img] Text (Skripsi)
PENGUJIAN HEAD LOSS PADA SISTEM PEMIPAAN SISTEM PENGENDALIAN LEVEL AIR SKALA LABORATORIUM.pdf
Restricted to Registered users only

Download (8MB)

Abstract

Head loss major obtained from friction losses along the pipe while the head loss minor head loss loss due to additional accessories such as elbow. Where the piping system is divided into 2, namely the piping system at the bottom pump and the pump top pumping system, the upper pumping pump system is divided into 3 sets of voltages ie 10 volts, 11 volts and 12 volts. In the lower pumping pump system obtained major head loss results of 0,0140 m with a length of pipe of 3.04 m and minor head loss in the lower pumping pump system obtained results of 0,0579 m with the number of elbow of 4 pieces ½ inch size. For head loss on pump top pumping system obtained head loss major result on 10 volt set equal to 1,37 m and minor head loss equal 1,01 m. On the 11 volts set obtained major head loss of 1,45 m and minor head loss of 1,07 m. Then for 12 volts set obtained major head loss of 1,52 m and minor head loss of 1,11 m. Where the length of the pipeline of the top 2.14 m pumping system with 2 elbow ½ inche.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
Thesis advisorListijorini, ErnyUNSPECIFIED
Thesis advisorDwinanto, DwinantoUNSPECIFIED
Additional Information: Head loss major obtained from friction losses along the pipe while the head loss minor head loss loss due to additional accessories such as elbow. Where the piping system is divided into 2, namely the piping system at the bottom pump and the pump top pumping system, the upper pumping pump system is divided into 3 sets of voltages ie 10 volts, 11 volts and 12 volts. In the lower pumping pump system obtained major head loss results of 0,0140 m with a length of pipe of 3.04 m and minor head loss in the lower pumping pump system obtained results of 0,0579 m with the number of elbow of 4 pieces ½ inch size. For head loss on pump top pumping system obtained head loss major result on 10 volt set equal to 1,37 m and minor head loss equal 1,01 m. On the 11 volts set obtained major head loss of 1,45 m and minor head loss of 1,07 m. Then for 12 volts set obtained major head loss of 1,52 m and minor head loss of 1,11 m. Where the length of the pipeline of the top 2.14 m pumping system with 2 elbow ½ inche.
Subjects: T Technology > T Technology (General)
Divisions: 03-Fakultas Teknik
03-Fakultas Teknik > 22201-Jurusan Teknik Sipil
Depositing User: Admin Eprints Untirta
Date Deposited: 19 Oct 2021 02:22
Last Modified: 19 Oct 2021 02:22
URI: http://eprints.untirta.ac.id/id/eprint/3228