Search for collections on EPrints Repository UNTIRTA

PERANCANGAN DISPLAY JALUR EVAKUASI DAN PENENTUAN TITIK KUMPUL DENGAN PENDEKATAN PENGUKURAN JARAK PADA GEDUNG PERKULIAHAN FAKULTAS TEKNIK UNTIRTA

Fadilah, Ratu Alfianur (2023) PERANCANGAN DISPLAY JALUR EVAKUASI DAN PENENTUAN TITIK KUMPUL DENGAN PENDEKATAN PENGUKURAN JARAK PADA GEDUNG PERKULIAHAN FAKULTAS TEKNIK UNTIRTA. S1 thesis, Fakultas Teknik Universitas Sultan Ageng Tirtayasa.

[img] Text (SKRIPSI)
RATU ALFIANUR FADILAH_3333190091_Fulltext.pdf
Restricted to Registered users only

Download (2MB)
[img] Text (BAB I)
RATU ALFIANUR FADILAH_3333190091_01.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB II)
RATU ALFIANUR FADILAH_3333190091_02.pdf
Restricted to Registered users only

Download (527kB)
[img] Text (BAB III)
RATU ALFIANUR FADILAH_3333190091_03.pdf
Restricted to Registered users only

Download (83kB)
[img] Text (BAB IV)
RATU ALFIANUR FADILAH_3333190091_04.pdf
Restricted to Registered users only

Download (754kB)
[img] Text (BAB V)
RATU ALFIANUR FADILAH_3333190091_05.pdf
Restricted to Registered users only

Download (319kB)
[img] Text (BAB VI)
RATU ALFIANUR FADILAH_3333190091_06.pdf
Restricted to Registered users only

Download (38kB)
[img] Text (DAFTAR PUSTAKA)
RATU ALFIANUR FADILAH_3333190091_Ref.pdf
Restricted to Registered users only

Download (270kB)
[img] Text (LAMPIRAN)
RATU ALFIANUR FADILAH_3333190091_Lamp.pdf
Restricted to Registered users only

Download (636kB)
[img] Text (PLAGIARISM CHECK)
RATU ALFIANUR FADILAH_3333190091_CP.pdf
Restricted to Registered users only

Download (16MB)

Abstract

The Faculty of Engineering UNTIRTA is a university located in Cilegon and has lecture building facilities to support various activities, so that many activities are carried out in this building. The problems found are the number of availability, deployment, and placement of displays, this building has not met the standards, the location of the gathering point is still too close to a building that has the potential to collapse and cannot accommodate a number of building occupants, 4 principles of display design in existing conditions have not applied the principles of proximity and symetry . This resulted in the display not being able to provide comprehensive information to evacuate in the event of an emergency. Then it is necessary to display appropriate evacuation routes and assembly points by using the distance measurement method, identify potential hazards, determine the location of assembly points and the routes used, and design evacuation route displays and assembly points. The identification and calculation results show that the evacuation facilities in the lecture building do not meet the standard criteria, the location of the gathering point used is in the Hijrah canteen parking lot with a capacity of 22,750 people and a distance of 87,82 meters from the BR building and a distance of 117,65 meters from the Letter building -U, the result of the design of the evacuation route display on a green base and white writing with 4 types of different sizes and 1 type of gathering point display on a green base and white writing.

Item Type: Thesis (S1)
Contributors:
ContributionContributorsNIP/NIM
Thesis advisorYadi, Yayan Harry197909022005011002
Thesis advisorDewantari, Nustin Merdiana1988080720190320009
Additional Information: Fakultas Teknik UNTIRTA merupakan Universitas yang berlokasi di Cilegon dan memiliki fasilitas gedung perkuliahan dalam menunjang berbagai kegiatan, sehingga banyak aktivitas yang dilakukan pada gedung ini. Permasalahan yang ditemukan yaitu jumlah ketersediaan, penyebaran, dan penempatan display, gedung ini belum memenuhi standar, lokasi titik kumpul masih terlalu dekat dengan gedung yang berpotensi runtuh dan belum dapat menampung sejumlah penghuni gedung, 4 prinsip perancangan display kondisi eksisting belum menerapkan prinsip proximity dan symetry. Hal tersebut mengakibatkan display tidak dapat memberikan informasi secara menyeluruh untuk mengevakuasi apabila terjadi keadaan darurat. Maka diperlukan display jalur evakuasi dan titik kumpul yang sesuai dengan menggunakan metode pengukuran jarak, melakukan identifikasi potensi bahaya, menentukan lokasi titik kumpul dan jalur yang digunakan, dan perancangan display jalur evakuasi dan titik kumpul. Hasil identifikasi dan perhitungan didapatkan sarana evakuasi pada gedung perkuliahan belum memenuhi kriteria yang sesuai standar, lokasi titik kumpul yang digunakan yaitu di parkir kantin hijrah dengan daya tampung 22.750 orang serta jarak tempuh sebesar 87,82 meter dari gedung BR dan jarak tempuh sebesar 117,65 meter dari gedung Letter-U, hasil rancangan display jalur evakuasi berwarna dasar hijau dan tulisan putih dengan 4 tipe ukuran yang berbeda dan 1 tipe display titik kumpul berwarna dasar hijau dan tulisan putih.
Subjects: T Technology > T Technology (General)
Z Bibliography. Library Science. Information Resources > Z665 Library Science. Information Science